GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

Brief Description:

GDSL-A Series?3-phase Primary Current Injection Test Set with Temperature Test is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy use and maintenance.

 

 

 

 

 


Product Detail

Product Tags

Functions

It has zero protection function to prevent the impact of large current from causing damage to the sample. It cannot be started when it is not at zero position.
Impact selection function, when the circuit breaker quick-break test is performed, the zero protection function can be cut off and the required current value can be directly output.
Output current mode: The true RMS value is continuously adjustable.
The output current is a standard sine wave, and the waveform distortion rate is less than 5%.
Voltage and current display adopts new high-precision LED digital display
Switchable size current range to improve display fineness for more accurate readings.
The power supply voltage and regulator output voltage can be switched to display for easy viewing.
The equipment capacity is designed for short-term, intermittent work in 5 minutes.
For batch testing, close for 10 minutes after 2.5 minutes of continuous operation.
It can measure the current action time of the tested component and record the lock action time synchronously. (optional)
Measured time range: 0.001S~999.999S Resolution 1ms, measurement error: 0.005% range ± 2digs. (optional)
The test value of primary current and secondary current can be directly displayed to facilitate the transformer ratio test. (optional)
Secondary current range 0~5A resolution 1mA (optional)
If the temperature rise (30 minutes - 24 hours) should be customized according to the long-term work temperature rise. (optional)
Can be customized three-phase with balance adjustment riser (optional)
Can be customized AC and DC riser (optional

Specifications

Input voltage: AC220V/380V ± 10% 50Hz ± 1.
Output current:: 0-15000A (according to customer demand).
Output voltage: 6V-24V(according to customer demand).
Duty cycle: 8hours(according to customer demand)
Ambient temperature: -10 ℃ to 50 ℃.
Current accuracy: ≤ 1.0% (F.S).
16-way temperature detection.(according to customer demand)