VLF-Series VLF Hipot Test System
The VLF Hipot Test System are truly compact and portable VLF test sets that determine the insulation condition of medlum voltage cables. Both test sets perform VLF and Dc testing, as well as sheath testing with sheath fault location possibilities.Its design complies with the international standard IEEE 400.2-2013.The VLF Hipot Test system combine a small and light weight VLF test set with integrated Tan Delta and Partial Discharge diagnostic modules to expand into a complete cable diagnostic system.
-
GDYD-63A AC/DC Hipot Test Set
GDYD-63A AC/DC Hipot Test Set is composed of automatic?control unit and AC oil?testing transformer?(HV unit) which output AC?voltage smoothly. Meanwhile, it has many monitoring and protection functions.?When the short circuit rod of testing transformer is taken out, the output is DC voltage.
-
GDVLF-80S VLF AC Hipot Test Set
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.
-
GDYT-10/100 Partial Discharge Testing System
GDYT-10/100 Partial Discharge Test System?is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer,?mutual inductor and lightning arresters.?It?is widely used in electrical manufacturing,?power operation departments, research institutes and universities.
-
GDYD-55D AC/DC Hipot Test Set
GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions.?
-
GDHX-9500B Phase Detector
GDHX-9500B?Phase Detector is mainly?used?in?electric power?lines,?phase?and?phase sequence calibration?in substation,?with?main?functions?including?electrical inspection,??phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference,?accorded with EMC standards, suitable for various electromagnetic interference situations.
-
GDCY-20P Impulse Voltage Test System
The equipment is according to?impulse voltage?testing requirement of the low-voltage power distribution system SPD II product?and solar battery, enable to generate impulse voltage (1.2/50μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments.
The equipment uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing.
-
GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester
In?the?power?system?and?factories,?mines,?enterprises?have?a?large?number of?electrical?equipment,?its?internal?insulation?are?oil-filled?insulation.?The dielectric?strength?test?of?the?insulating?oil?is?a?routine?test?must?be?measured.
In?order?to?adapt?to?the?needs?of?the?rapid?development?of?the?power industry,?the?new?version GDOT-3B Insulation oil?BDV?tester increase?the?standards?and?methods?of?selection?and?other?content,?simplify the user’s operation, to facilitate the application of the user for different conditions?of?use.?This?product?is?based?on?the?new?test?protocol?DL/T?596-2005 and the corresponding national standard GB/T 507-2002 and DL/T 429.9-91 design and manufacture, the use of micro-single-chip computer control, electromechanical integration of all automation, high measurement accuracy, greatly improving the efficiency of the work, but also greatly reduces the staff’s labor intensity.
?
-
GDJB-1200A Six Phase Relay Protection Test Set
GDJB-1200A Six Phase Relay Protection Microcomputer Test Device plays a key role in operating electricity power systems reliably and safely. It is the testing device used in professional field of microcomputer protection, relay protection, excitation measurement, fault recorder.
-
GDBT-10000kVA/36kV Transformer Test System
GDBT-10000kVA/36kV?is mainly to make no-load?and load test, power frequency withstand voltage test, induction withstand voltage test, temperature rising test, DC resistance test and ratio test for 36kV, 10000kVA and below distribution transformers.
-
GDYD-1210D AC Hipot Test Set
GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions.?
-
GDSF-411WPD 3-in-1 SF6 Gas Analyzer(with pump)
GDSF-411WPD is an ideal instrument when it is necessary to test water content, purity, and decomposition products of SF6 gas. The core component of dew point test is DRYCAP? series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer.